Hệ thống Giám sát và Bảo vệ nguồn
J312-7 Novaris HSG3-200-480 Hybrid Surge Diverter 3 Phase, 200kA 8/20us Uc 480VAC, All Mode, single enclosure
Hybrid Spark Gap
Use Hybrid Spark Gap high energy surge diverters for point of entry protection at main switchboards where grid instability is an issue.
Hybrid Protection
The Hybrid Spark Gap design combines a spark gap and MOV in series to improve the overvoltage tolerance of the surge protector. This combination allows the HSG to be exposed to continuous over voltage of up to 480V while still providing a low voltage protection level.
LED Status Active Display
The LED display indicates segment status and indicates normal operation when all LEDs are brightly lit. A dim LED phase segment indicates the failure of an external backup fuse and this will activate the external alarm. An extinguished LED indicates a component failure or thermal overload, also activating the external alarm.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclousures. In the event of a prolonged overvoltage they will not catch fire or explode.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-23 Novaris IFD2-32-50-460-A Isolated Surge Filter, 1 Phase, 32A, 50kA, 460V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-17 Novaris IFD2-20-100-275-A Isolated Surge Filter, 1 Phase, 20A, 100kA, 275V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-9 Novaris IFD2-10-50-275-A Isolated Surge Filter, 1 Phase, 10A, 50kA, 275V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge ×lters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-21 Novaris IFD2-32-50-150-A Isolated Surge Filter, 1 Phase, 32A, 50kA, 150V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-22 Novaris IFD2-32-50-275-A Isolated Surge Filter, 1 Phase, 32A, 50kA, 275V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-24 Novaris IFD2-32-100-150-A Isolated Surge Filter, 1 Phase, 32A, 100kA, 150V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-18 Novaris IFD2-20-100-460-A Isolated Surge Filter, 1 Phase, 20A, 100kA, 460V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-16 Novaris IFD2-20-100-150-A Isolated Surge Filter, 1 Phase, 20A, 100kA, 150V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge ×lters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-26 Novaris IFD2-32-100-460-A Isolated Surge Filter, 1 Phase, 32A, 100kA, 460V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J310-6 Novaris SDH2-40-2400-M Replacement Module for SDH2-40-2400
High voltage surge diverter for air¦eld lighting
Modern solar inverter systems are vital for renewable energy systems, as these systems are spread over a large area and are susceptible to damage by direct lightning strikes and nearby ground strikes that can result in induced surges also causing damage. Such damage can result in compromised safety and downtime to operations. Novaris SDH2 provides maximum protection for solar systems by providing 3 Phase to earth protection. The high operating voltage allows for their use on all 800V systems, and the 40k surge rating provides robust protection. They incorporate internal thermal safety disconnects, ensuring safe disconnection in the event of the unit reaching its end of life, and allowing the solar system to remain operational, visual indication and alarm contacts for condition monitoring.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J326-7 Novaris SFM3-40-50-275 Surge filter, 40A, 3ph, 50kA
Medium Current Filters
Novaris SFM filters provide the highest level of protection with the lowest let through voltage. Installation at a main switch board will protect all the connected downstream equipment.
Percentage Active Display
A digital display confirms the device rating by displaying the percentage active of the redundant segments. The display indicates segment status and thermal overload.
Three Stages of Protection
Novaris surge filters have 2 stages of varistor protection separated by a low pass LC filter. This 3 stage combination reduces the effects of high frequency noise and transients to provide the highest level of protection to sensitive loads.
All Mode Protection
Protection is provided for all combinations of lines (L-L, L-N, L-E, N-E) ensuring the maximum level of protection is achieved at all times.
Active Alarm
Fail-safe alarm contact allows for remote monitoring.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J309-2 Novaris SDPV-100-1000-M Replacement Module for SDPV-100-1000
Solar Protector
Novaris SDPV's are designed for photovoltaic system DC-side protection against the damage from surges caused by lightning or over voltages.
Replaceable pluggable elements
Pluggable design allows for easy removal and replacement.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
SPM91 - Đồng hồ năng lượng một pha lắp ray DIN
Chức năng cơ bản
- Phù hợp cho hệ thống hạ thế 110V, 120V, 220V, 230V, 240V AC
- Đo các thông số: U, I, P, Q, S, PF, kWh, Kvarh; Hiển thị LCD: U, I, P, kWh
- Hiển thị LCD 6+1 dãy số (999999.9 kWh)
- LED hiển thị xung đầu ra
- Bảo vệ với mật khẩu
- Một nút điều khiển trang lên/xuống, một nút để lập trình
- Kích thước nhỏ gọn: 100*36*65mm
- Cổng RS485, giao thức MODBUS-RTU hoặc DL/T645 (tùy chọn)
- Lắp trên ray DIN, DIN ED5002 tiêu chuẩn
- Tiêu chuẩn: IEC62053-21
- Hãng sản xuất :
- Kích thước :
J322-13 Novaris IFD2-20-50-150-A Isolated Surge Filter, 1 Phase, 20A, 50kA, 150V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge ×lters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-15 Novaris IFD2-20-50-460-A Isolated Surge Filter, 1 Phase, 20A, 50kA, 460V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge ×lters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J306-2 Novaris IDD3-100-D480 Isolated Surge Diverter, 3 phase delta, 100kA, 480V L-L
Delta Connected Surge Diverter
The Novaris IDD3 range has been designed for use in delta connected systems and is DIN compliant.
All Mode Protection
Protection is provided for all combinations of lines ensuring the maximum level of protection is achieved at all times.
Thermal Sensing
Sustained overvoltages can cause components to overheat and degrade. Thermal sensing warns of this condition without disconnecting the protection.
LED Status Active Display
The LED display indicates phase status and normal operation when all LEDs are lit. An extinguished LED indicates a component failure or thermal overload.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.
Optional Alarm Feature
An optional voltage free alarm (suf×x -A) contact is available, providing the ability to remotely monitor both power and the status of the SPD.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J306-1 Novaris IDD3-50-D480 Isolated Surge Diverter, 3 phase delta, 50kA, 480V L-L
Delta Connected Surge Diverter
The Novaris IDD3 range has been designed for use in delta connected systems and is DIN compliant.
All Mode Protection
Protection is provided for all combinations of lines ensuring the maximum level of protection is achieved at all times.
Thermal Sensing
Sustained overvoltages can cause components to overheat and degrade. Thermal sensing warns of this condition without disconnecting the protection.
LED Status Active Display
The LED display indicates phase status and normal operation when all LEDs are lit. An extinguished LED indicates a component failure or thermal overload.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode.
Optional Alarm Feature
An optional voltage free alarm (suf×x -A) contact is available, providing the ability to remotely monitor both power and the status of the SPD.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J334-1 Novaris SSP10A-38 Series Surge Protector 38V 15kA c/w base
Series Surge Protector 10A
The Novaris SSP10A is a surge protection device designed to protect AC and DC low voltage power supplies. The SSP10A has zero earth leakage current and will prevent the tripping of supply fuses down to 2A should a transient overvoltage occur. The SSP10A is DIN rail mountable and is locked onto the DIN rail when the earth lug screw is tightened.
Failsafe Design
In the event of an excessive common mode surge, a fuse will rupture isolating the earth thereby preventing a short circuit to earth. This is critical for applications like railway signaling.
Indicating Fuse
Should the earth fuse rupture a red indicating flag will pop up and a normally closed voltage free contact will change state.
External Alarm
In the event the earth fuse ruptures a normally closed alarm contact will open providing means for remote monitoring.
Pluggable Design
The pluggable design allows for easy removal and replacement.
Power Indicator
An LED indicates the presence of power.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
J322-20 Novaris IFD2-32-50-130-A Isolated Surge Filter, 1 Phase, 32A, 50kA, 130V, Alarm contact
Two Phase DIN Mount Surge Filters
The Novaris IFD2 range of surge filters is designed for protecting foating AC or DC power supplies. Applications include DC power supplies, balanced circuits for rail applications and single phase IT systems.
Multistage Protection
The IFD2 uses 3 stages of protection to provide a low let through voltage. The first stage comprises a delta con×guration of metal oxide varistors to provide clamping between both lines and between each line and earth. The second stage is a low pass filter providing instantaneous protection against high frequency impulses. The third stage is a line to line metal oxide varistor to provide an extra level of protection against primary and load side surges.
No Earth Leakage
The IFD2 configuration results in zero earth leakage under normal operating conditions. The earth reference for the product is isolated using a spark gap. This means even in the event of a short circuit failure within the device, no current will pass to earth.
Safe Metal Enclosure
Novaris power protection products are housed in safe, all metal enclosures. In the event of a prolonged overvoltage they will not catch fire or explode. Installation Independent Performance
Series surge protectors such as the SSP and IFD range house the shunt (parallel) connection of the protection components internally within the device. This reduces the connection impedance to a minimum to guarantee optimal performance in all installations.
Xuất xứ: Australia/ Malaysia
- Hãng sản xuất :
- Kích thước :
PMAC202 AC - Đồng hồ mạch nhánh
Chức năng
- Đo: 1 mạch chính + 42 mạch nhánh
- DI/DO: 4 đầu vào trạng thái (dry contact), 2 rơ le đầu ra, 1 xung đầu ra
- Chức năng cảnh báo trước có thể cài đặt
- Mạch chính: Cảnh báo điện áp, dòng, mất cân bằng dòng (tùy chọn cho rò rỉ dòng, cảnh báo nhiệt độ)
- Mạch nhánh: Cảnh báo dòng (lo-lo-limit, lo-limit, hi-limit, hi-hi-limit)
- Giao tiếp: RS485, hỗ trợ giao thức Modbus-RTU
- Thứ tự pha của mạch nhánh có thể lập trình được
- Tùy chọn đầu vào biến dòng cho mạch nhánh: 50A, 100A, 200A
- Cài đặt hệ thống dây cho mạch nhánh: một pha hoặc ba pha
- Ghi nhớ lịch sử tiêu thụ kWh: lượng tiêu thụ kWh hàng năm của 10 năm gần nhất, lượng tiêu thụ hàng tháng của 12 tháng gần nhất
- Hãng sản xuất :
- Kích thước :
PMAC203 - Đồng hồ mạch nhánh 1 chiều
Điện áp hệ thống nguồn một chiều
- 240VDC với cảm biến Hall 24VDC
- 48VDC với cảm biến Hall +/- 12VDC
- Mức điện áp DC có thể thay đổi được từ 48~400VDC
Chức năng
- Đo: 1 mạch chính + 42 mạch nhánh
- DI: 4 đầu vào trạng thái (dry contact) cho thiết bị đóng cắt chính và công tắc chống sét
- DO: 2 đầu ra rơ le để cảnh báo, 1 xung đầu ra
- Chức năng cảnh báo trước có thể thiết lập được
Mạch chính: Cảnh báo điện áp, dòng, tải, trạng thái đóng cắt. Cảnh báo tùy chọn cho điện trở cách điện và nhiệt độ
Mạch nhánh: Cảnh báo dòng (lo-lo-limit, lo-limit, hi-limit, hi-hi-limit), trạng thái đóng cắt. Tùy chọn với điện trở cách điện
- Giao tiếp: RS485, hỗ trợ giao thức Modbus-RTU
- Tùy chọn cảm biến hall đầu vào cho mạch chính: 100A, 200A, 400A, 600A, 800A, 1600A
- Tùy chọn cảm biến hall đầu vào cho mạch nhánh: 50A, 100A, 200A
- Cảm biến hall hiệu chuẩn điểm không
- Giám sát trạng thái mạch chính và nhánh tùy chọn
- Giám sát cách ly và nhiệt độ
- Ghi nhớ lịch sử tiêu thụ kWh: tiêu thụ kWh hàng năm của 10 năm gần nhất, tiêu thụ kWh hàng tháng của 12 tháng gần nhất
- Hãng sản xuất :
- Kích thước :
PMAC211 - Đồng hồ năng lượng đa dòng
Đặc điểm
- Phù hợp cho chế độ kết nối 3 pha 4 dây
- Sử dụng để đo AC 4x3 pha
- Hiển thị LCD: U, I, P, Q, S, PF, F, kWh, kvarh
- Cảnh báo quá và dưới ngưỡng, ghi nhận lên đến 500 cảnh báo
- Dòng đo tối đa lên đến 600A
- Dòng định mức đầu vào 33.3mA & 100mA (tùy chọn)
- Đèn LED hiển thị cảnh báo và trạng thái giao tiếp
- Lắp thanh DIN 35mm tiêu chuẩn
Chức năng chính
Đo thời gian thực
- Điện áp, dòng, công suất, công suất phản kháng, công suất biểu kiến, hệ số công suất, tần số, năng lượng, năng lượng phản kháng
Chức năng cảnh báo và ghi nhớ cảnh báo quá và dưới ngưỡng
- Quá áp, thấp áp, quá dòng
Giao tiếp
- Cổng 1 RS485, giao thức MODBUS-RTU
Ghi dữ liệu mỗi 15 phút
- Hãng sản xuất :
- Kích thước :
SPM93 - Đồng hộ năng lượng 3 pha lắp ray DIN
Chức năng cơ bản:
- Phù hợp với hệ thống hạ thé 110V, 120V, 220V, 230V, 240V AC
- Hiển thị LCD 7+1 dãy số (9999999.9 kWh)
- Đo các thông số V, I, P, Q, S, PF, F, kWh, kvarh
- Ghi nhận lịch sử năng lượng cho muộn nhất 31 ngày (mỗi 15 phút), muộn nhất 12 tháng và muộn nhất 10 năm
- Đo kWh chính xác hạng 1.0
- Hỗ trọ chức năng đo thời gian quá áp, điện áp thấp và quá dòng
- 2 đèn LED hiện thị xung (có thể cài đặt cho kWh hoặc kvarh)
- Hiển thị LCD tức thời cho các lỗi về trình tự pha
- 3 nút lập trình, lắp đặt trên ray DIN 35mm, DIN ED5002 tiêu chuẩn
- Một cổng RS485, giao thức MODBUS hoặc DL/T645 (tùy chọn)
- Tiêu chuẩn: IEC62053-21/23
- Hãng sản xuất :
- Kích thước :